Florida AHJ

Solar permit requirements in Un-incorporated St. Johns, FL

Solar installers and homeowners in Un-incorporated St. Johns must comply with specific structural and design standards for PV installations. Solar Design Lab provides permit-ready plansets that meet these local requirements.

Requirements at a glance

Design wind speed
130 mph (ASCE)
Exposure category
B
Ground snow load
0 psf
High-velocity hurricane zone
No
Submission format
Digital submission
Separate discipline files
No

What Un-incorporated St. Johns expects on a solar permit

All roof-mounted PV systems in Un-incorporated St. Johns require a structural engineering letter. Designs must adhere to a 130 mph wind speed and Exposure Category B per FBC 2023 and ASCE 7-22. The jurisdiction accepts digital submissions.

  • [structural] Provide a structural engineering letter for all roof-mounted PV systems.
  • [structural] Design structural criteria to 130 mph wind speed and Exposure Category B per FBC 2023/ASCE 7-22.

Design a permit-ready Un-incorporated St. Johns planset with these rules baked in.

Solar Design Lab derives the SLD, electrical, and structural live as you draw, and checks your design against Florida AHJ requirements before you submit. First planset free.