Solar installations in Lady Lake, Florida, must adhere to specific structural and documentation standards. These requirements ensure that all residential and commercial solar projects comply with local building codes.

Requirements at a glance

Design wind speed
140 mph (ASCE)
Exposure category
B
Ground snow load
0 psf
High-velocity hurricane zone
No
Submission format
Hard copy required
Separate discipline files
No

What Lady Lake expects on a solar permit

Projects must be designed for a 140 mph wind speed and Exposure Category B per FBC 2023 and ASCE 7-22. Structural specifications require that lag screws have at least 3 inches of embedment into the roof trusses. Submissions must include a signed Engineer Letter of Compliance confirming special inspection results and that the installation meets the intent of FBC 2023. Lady Lake requires hardcopy submission for all permit applications.

  • [documentation] Provide a signed Engineer Letter of Compliance (affidavit) confirming special inspection results and that the structural and electrical installation meets the intent of FBC 2023.
  • [structural] Design structural calculations to meet 140 mph wind speed and Exposure Category B per FBC 2023 and ASCE 7-22.
  • [structural] Specify that lag screws must have at least 3 inches of embedment into the roof trusses.

Design a permit-ready Lady Lake planset with these rules baked in.